Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 91(6): 2612-2620, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38247037

RESUMO

PURPOSE: Measure the changes in relative lung water density (rLWD), lung volume, and total lung water content as a function of time after supine body positioning. METHODS: An efficient ultrashort-TE pulse sequence with a yarnball k-space trajectory was used to measure water density-weighted lung images for 25 min following supine body positioning (free breathing, 74-s acquisitions, 3D images at functional residual capacity, 18 time points) in 9 healthy volunteers. Global and regional (10 chest-to-back positions) rLWD, lung volume, and total lung water volume were measured in all subjects at all time points. Volume changes were validated with a nitrogen washout study in 3 participants. RESULTS: Global rLWD increased significantly (p = 0.001) from 31.8 ± 5.5% to 34.8 ± 6.8%, while lung volumes decreased significantly (p < 0.001) from 2390 ± 620 mL to 2130 ± 630 mL over the same 25-min interval. Total lung water volume decreased slightly from 730 ± 125 mL to 706 ± 126 mL (p = 0.028). There was a significant chest-to-back gradient in rLWD (20.7 ± 4.6% to 39.9 ± 6.1%) at all time points with absolute increases of 1.8 ± 1.2% at the chest and 5.4 ± 1.9% at the back. Nitrogen washout studies yielded a similar reduction in lung volume (12.5 ± 0.9%) and time course following supine positioning. CONCLUSION: Lung volumes during tidal breathing decrease significantly over tens of minutes following supine body positioning, with corresponding increases in lung water density (9.2 ± 4.4% relative increase). The total volume of lung water is slightly reduced over this interval (3.3 ± 4.0% relative change). Evaluation of rLWD should take time after supine positioning, and more generally, all sources of lung volume changes should be taken into consideration to avoid significant bias.


Assuntos
Pulmão , Posicionamento do Paciente , Humanos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Respiração , Nitrogênio , Decúbito Dorsal
2.
Children (Basel) ; 10(11)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-38002857

RESUMO

Supracondylar fractures are common injuries in children. Diagnosis typically relies on radiography, which can involve long wait times in the ED, emits ionizing radiation, and can miss non-displaced fractures. Ultrasound (US) has the potential to be a safer, more convenient diagnostic tool, especially with new highly portable handheld 2D point of care US (POCUS). This study aimed to determine the reliability of 2D POCUS for the detection of supracondylar fractures and elbow joint effusions, to contrast the accuracy of 2D POCUS vs. 3DUS vs. radiographs, and to determine whether blinded image interpretation could produce similar results to non-blinded real-time imaging. Fifty-seven children were scanned with 2D POCUS and 3DUS on the affected elbow. US scans were then read by three blinded readers, and the results were compared to gold-standard radiographs. Compared to a gold standard of 30-day radiographic diagnosis, readers of 2D POCUS detected supracondylar fracture and effusion with sensitivities of 0.91 and 0.97, respectively, which were both higher than with 3DUS. Inter-rater reliability of fracture detection was moderate for 2D POCUS (k = 0.40) and 3DUS (k = 0.53). Consensus sensitivities, although high, were lower than reports from some non-blinded studies, indicating that clinical presentation serves as an important factor in detection rates. Our results from consensus US diagnosis support the validity of using 2D POCUS in children for supracondylar fracture and elbow effusion diagnosis.

3.
Sci Rep ; 13(1): 14535, 2023 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-37666945

RESUMO

Wrist trauma is common in children and generally requires radiography for exclusion of fractures, subjecting children to radiation and long wait times in the emergency department. Ultrasound (US) has potential to be a safer, faster diagnostic tool. This study aimed to determine how reliably US could detect distal radius fractures in children, to contrast the accuracy of 2DUS to 3DUS, and to assess the utility of artificial intelligence for image interpretation. 127 children were scanned with 2DUS and 3DUS on the affected wrist. US scans were then read by 7 blinded human readers and an AI model. With radiographs used as the gold standard, expert human readers obtained a mean sensitivity of 0.97 and 0.98 for 2DUS and 3DUS respectively. The AI model sensitivity was 0.91 and 1.00 for 2DUS and 3DUS respectively. Study data suggests that 2DUS is comparable to 3DUS and AI diagnosis is comparable to human experts.


Assuntos
Fraturas Ósseas , Fraturas do Punho , Traumatismos do Punho , Humanos , Criança , Inteligência Artificial , Ultrassonografia
4.
J Clin Densitom ; 24(4): 651-657, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33531205

RESUMO

High resolution peripheral quantitative computed tomography (HR-pQCT) was designed to study bone mineral density (BMD) and microarchitecture in peripheral sites at the distal radius and tibia. With the introduction of the second generation HR-pQCT scanner (XtremeCT II, Scanco Medical) that has a larger, longer gantry it is now possible to study the human knee in vivo using HR-pQCT. Previous validation of HR-pQCT measurements at the distal radius and tibia against micro-CT is not representative of the knee because the increased cross-sectional area, greater amount of soft tissue surrounding the scan region, and different imaging protocol result in potentially increased beam hardening effects and photon scatter and different signal-to-noise ratio. The objective of this study is to determine the accuracy of density and microarchitecture measurements in the human knee measured by HR-pQCT using an in vivo protocol. Twelve fresh-frozen cadaver knees were imaged using in vivo HR-pQCT (60.7 µm) protocol. Subsequentially, distal femurs were extracted and imaged using a higher resolution (30.3 µm) ex vivo protocol, replicating micro-CT imaging. Scans were registered so that agreement of density and bone microarchitecture measurements could be determined using linear regression and Bland-Altman plots. All density and microarchitecture outcomes were highly correlated between the 2 protocols (R2 > 0.89) albeit with statistically significant differences between absolute measures based on paired t tests. All parameters showed accuracy between 4.5% and 8.7%, and errors were highly systematic, particularly for trabecular BMD and trabecular thickness (R2 > 0.93). We found that BMD and microarchitecture measurements in the distal femur obtained using an in vivo HR-pQCT knee protocol contained systematic errors, and accurately represented measurements obtained using a micro-CT equivalent imaging protocol. This work establishes the validity and limitations of using HR-pQCT to study the BMD and microarchitecture of human knees in future clinical studies.


Assuntos
Densidade Óssea , Fêmur , Fêmur/diagnóstico por imagem , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Suporte de Carga
5.
Respir Med Case Rep ; 22: 44-46, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28652964

RESUMO

We report a case of tonsillar histoplasmosis with hematogenous dissemination in a woman receiving infliximab for Crohn's disease. She also had a history of sarcoidosis. Due to the unusual location and confounding medical history, our case provided a diagnostic dilemma. Histoplasma infection was confirmed histologically, and the patient responded well to appropriate treatment.

6.
Acta Biomater ; 3(5): 651-61, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17513181

RESUMO

Electrospinning can be used to selectively process a variety of natural and synthetic polymers into highly porous scaffolds composed of nano-to-m diameter fibers. This process shows great potential as a gateway to the development of physiologically relevant tissue engineering scaffolds. In this study, we examine how incremental changes in fiber alignment modulate the material properties of a model scaffold. We prepared electrospun scaffolds of gelatin composed of varying fiber diameters and degrees of anisotropy. The scaffolds were cut into a series of "dog-bone" shaped samples in the longitudinal, perpendicular and transverse orientations and the relative degree of fiber alignment, as measured by the fast Fourier transform (FFT) method, was determined for each sample. We measured peak stress, peak strain and the modulus of elasticity as a function of fiber diameter and scaffold anisotropy. Fiber alignment was the variable most closely associated with the regulation of peak stress, peak strain and modulus of elasticity. Incremental changes, as judged by the FFT method, in the proportion of fibers that were aligned along a specific axis induced incremental changes in peak stress in the model scaffolds. These results underscore the critical role that scaffold anisotropy plays in establishing the material properties of an electrospun tissue engineering scaffold and the native extracellular matrix.


Assuntos
Materiais Biocompatíveis/química , Matriz Extracelular/química , Gelatina/química , Engenharia Tecidual/métodos , Anisotropia , Elasticidade , Eletroquímica/métodos , Teste de Materiais , Rotação , Resistência à Tração , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...